Maximum flexibility
Modular design, more beautiful and consistent appearance; arbitrary combination between modules
Multiple models are available for use in various conditions
Multiple optional accessories to adapt to various environmental requirements
Each unit is equipped with an adjustable speed fan as standard, and there is no need to consider the
pressure balance problem when using it in combination
High-efficiency fan
Using the variable speed new impeller high-efficiency fan, the static pressure can be adjusted from 20Pa to 450Pa,
combined with the specially designed large static pressure chamber, the low noise of Himod air conditioner can be achieved
Energy saving
Due to the use of high-efficiency fans and scroll compressors, the power consumption of Himod air conditioner
is greatly reduced (35% lower than traditional models), and the operation and maintenance costs are low
Intelligent control
Each module is controlled by a new microcomputer controller. Multi-module units can realize interconnection
and program control without adding any equipment, and remote networking can be achieved through the controller.
Easy and convenient installation and maintenance
Complete full front maintenance, simple component disassembly and maintenance, and very short mean time to repair.
No space is required on the side of the unit, saving installation space. The humidification adopts detachable
electrode humidification with automatic flushing function, the heater adopts three-stage electric heating, and
the air outlet is equipped with a flow equalizer as standard.
Environmental protection
Himod uses recyclable industrial materials, which plays a positive role in environmental protection
Sandwich sandwich panel structure, with flame-retardant insulation and noise reduction materials in the middle,
has A0 fireproof performance.
Unit parameter configuration table | |||||
No. | Name | Parameters | Brand | ||
1 | model | M41 | Heroth | ||
2 | Unit performance | blowing rate (m³/h) | 12470 | ||
3 | Cold volume (kw) | 45.8 | |||
4 | Input power in nominal refrigeration condition (kw) | 10 | |||
Quantity of compressor | 1 | ||||
5 | Heat production (electric heating) (kw) | ||||
6 | Input power in nominal heating condition (kw) | ||||
7 | External residual pressure (static pressure) (Pa) | 380 | |||
8 | Temperature control range is (℃) | 18~31 | |||
9 | source | 380V 50Hz | |||
10 | cryogen | R22 | R410a R407c | ||
11 | Energy saving way | Electronic expansion valve | |||
12 | energy management | 25.50.75.100 | |||
13 | Electrical heating type | electrode | |||
14 | Electric heating power (kw) | 15 | |||
15 | Type of humidifier | The electrode type | |||
16 | Humidification amount (kg) | 13 | |||
17 | Humidifier power (kw) | 9 | |||
18 | Humidifier pipe diameter: (Φ) | ||||
19 | Humidity control range | 40~75 | |||
20 | an indoor unit | Evaporator type | Copper tube sleeve aluminum fin | ||
21 | air filter | The initial effect | |||
22 | Indoor fan type | Low-noise centrifugal fan | |||
23 | Indoor fan power | ||||
24 | External dimensions (indoor) | ||||
25 | Unit weight | ||||
26 | an outdoor unit | Condenser type | Copper tube sleeve aluminum fin | ||
27 | Outdoor fan type | Low-noise axial flow fan | |||
28 | Power of outdoor fan | ||||
29 | External dimensions (outdoor) | ||||
30 | Unit weight | ||||
31 | other | Return to the wind | Horizontal air supply air, horizontal return air | ||
32 | Indoor and outdoor machine link pipe | copper pipe | |||
33 | Link form | weld | |||
quantity | 2 | ||||
caliber | 28/22 | ||||
34 | noise dB(A) | 58 | |||
35 | Remote control system interface | RS485/RS232 | |||
36 | With the power-off memory function | Automatic power-on after power outage and reset | |||
37 | With the temperature and humidity early warning function | The alarm parameters can be set | |||
Unit wiring |