Beijing Ding Ding Future Technology Co.Ltd

Let our small works lighting big world

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Telecom Power System /

Eltek 241115.105 Flatpack2 48V 24kw Eltek AC DC Rectiverter 2U Power Core CTOR0402.1

Contact Now
Beijing Ding Ding Future Technology Co.Ltd
Visit Website
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:MrLee
Contact Now

Eltek 241115.105 Flatpack2 48V 24kw Eltek AC DC Rectiverter 2U Power Core CTOR0402.1

Ask Latest Price
Video Channel
Brand Name :Eltek
Model Number :CTOR0402.1xxx
Certification :CE, UL
Place of Origin :CN
MOQ :1 set
Price :1800 USD / 3500 USD
Payment Terms :L/C, T/T
Supply Ability :500 sets per month
Delivery Time :8-10 weeks
Packaging Details :Carton pacaked
Brand :Eltek
Input AC :185-275 VAC / 170 VA
DC output current :100 A
DC output voltgae :53,5 VDC / 43-58 VD
Max power capacity :4800 W
Rectifeir Part No. :241115.105
Rectifeirs :Flatpack2 48/2000HE /Flatpack2 48/3000HE
Controller :Smartpack2 Touch or Smartpack Panel
System dimension :19 x 14,9 x 12,2 "inch
Height :4U
Weight :less than 15 kg
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

AC DC Rectiverter 2U Power Core 6kVA AC 4.8KW DC Smartpack R controller (Part No.:CTOR0402.1xxx)

Eltek 241115.105 Flatpack2 48V 24kw Eltek AC DC Rectiverter 2U Power Core CTOR0402.1

The rectiverter 2U power core combines both AC and DC feed into one 2U compact unit. Make it provides AC backup power for 230Vac or 115Vac loads; and 48Vdc power for DC loads and battery charging.

The total output power for both AC and DC is limited to a total 8KW, AC and DC output limits can be set according to the connected load, where the limitation for AC load is set to mas 6kVA and for DC load for max 4KW or 8KW.

Applications :

TELECOM-MOBILE/WIRELESS

· LTE/4G/WiMAX

· Distributed antenna system

· Broadband

· Radio base stations/cell sites

POWER UTILITIES

· Low & High voltage switchgear

· Transformer & SUB stations

· Control & protection

· SCADA system

RAILWAY & METRO INFRASTRUCTURE

· Control & protection

· Signaling

Key Features :

l Compact design and simple installation

l Single phase 230 or 115VAC input and output

l 48Vdc input and output

l Up to 4 rectiverter modules

l 8KW total AC+DC output

l Max 6kVA AC output

l Max 4KW/ 8KW DC output

l 1 or 2 pole AC distribution options

l 1 Pole DC distribution option

l Built in transfer technology

Techinical Data:

Models 8 kW, 230 VAC 4 kW, 115 VAC
Product family CTOR0402.1xxx CTOR0402.1xxx
AC OUTPUT DATA
Voltage (default) / (adjustable range) 1) 230 VAC / 200-240 VAC 115 VAC / 100-127 VAC
Frequency (inverter mode – default) 50 Hz (adaptive) 60 Hz (adaptive)
Frequency (inverter mode – settable) 50 Hz, 60 Hz or last synced 50 / 60 Hz (adaptive)
Power maximum (continuous / overload <15s) 4800 W (6000 VA) / 8000 VA 2400 W (3000 VA) / 4000 VA
Current maximum (continuous / overload <15s) 26 ARMS / 34,8 ARMS
Current (maximum) quick trip (20ms) 128 A (6 x nominal)
Hold up (Voltage dips) (before switching to battery) 5 ms 5 ms
THD < 1,5 % at resistive load
Protection Fuse in L, Hot pluggable, Varistor
DC OUTPUT DATA
Voltage (default) / (adjustable range) 53,5 VDC / 43-58 VDC
Power (maximum @nominal input) 4800 W 2) 2400 W 2)
Current (maximum @VOUT ≤ 108 VDC) 100 A 2) 50 A 2)
Current sharing (10 - 100% load) ±5 % of maximum current from 10 to 100 % load
Protection Short circuit proof, Over voltage shutdown, Reversed polarity and Fuse
INPUT DATA
AC Mains Input Voltage (range / LV disconnect) 185-275 VAC / 170 VAC 95-140 VAC / 85 VAC
AC Current (maximum - depends on module type) 32,8-46 ARMS 3) 36,8-45,2 ARMS 3)
Frequency (default: sync range) 47-53 & 57-63 Hz 57-63 & 47-53 Hz
Frequency (settable: sync range) 47-53 Hz, 57-63 Hz or both (adaptive)
Power Factor / THD > 0,99 at 70% load or more / < 3,5 %
DC Voltage nominal / extended range 4) 45-58 VDC / 40-45 VDC
DC Current (maximum) 128 A / 180 A during overload (15 s) 64 A / 90 A during overload (15 s)
Input features

Fuse in L and N, Hot pluggable, Varistor

AC input individual screw terminals 4 mm2 for L, N & PE (4x single phase)

OPTIONS
Control unit Smartpack R
Alarm connection Extension Alarm Card (6x Digital Inputs & 6x Relays)
Battery distribution Max. 2x 100 A or 1x 150 A
LVBD 150A (optional)
AC distribution Max. 3x 16 A (1 pole) or 1x 16 A (2 pole) MCBs
DC distribution Max. 3x 60 A (1 pole) MCBs
OTHER SPECIFICATION
Efficiency > 96 % (mains mode), > 94 % (inverter mode) > 92 % (mains mode), > 91 % (inverter mode)
Operating temperature -40 to +55 °C (-40 to +131 °F), humidity 5-95 % RH non-condensing
Storage temperature -40 to +85 °C (-40 to +185 °F), humidity 0-99 % RH non-condensing
Dimensions [W x D x H] 483 x 386 x 97 mm (19 x 15,2 x 3,8 inch)
Weight 9,9 kg (21,8 lbs)
DESIGN STANDARDS
Electrical safety EN 60950-1, EN 62040-1 UPS safety

EMC

ETSI EN 300 386 V2.1.1, FCC CFR 47 Part 15

EN 62040-2

EN 61000-6-1/-2/-3/-4

Environment

ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) & 2-3 (Class 3.2)

Normal operating conditions as per IEC 62040-3:2011 clause 4.2. Other operating conditions as per IEC 62040-3:2011 clause 4.3, must be advised

RoHS 3 (2015/863/EU) and WEEE (2008/98/EC) compliant

Eltek 241115.105 Flatpack2 48V 24kw Eltek AC DC Rectiverter 2U Power Core CTOR0402.1

Eltek 241115.105 Flatpack2 48V 24kw Eltek AC DC Rectiverter 2U Power Core CTOR0402.1Eltek 241115.105 Flatpack2 48V 24kw Eltek AC DC Rectiverter 2U Power Core CTOR0402.1

Eltek 241115.105 Flatpack2 48V 24kw Eltek AC DC Rectiverter 2U Power Core CTOR0402.1Eltek 241115.105 Flatpack2 48V 24kw Eltek AC DC Rectiverter 2U Power Core CTOR0402.1Eltek 241115.105 Flatpack2 48V 24kw Eltek AC DC Rectiverter 2U Power Core CTOR0402.1

Eltek 241115.105 Flatpack2 48V 24kw Eltek AC DC Rectiverter 2U Power Core CTOR0402.1Eltek 241115.105 Flatpack2 48V 24kw Eltek AC DC Rectiverter 2U Power Core CTOR0402.1

Eltek 241115.105 Flatpack2 48V 24kw Eltek AC DC Rectiverter 2U Power Core CTOR0402.1

Solutions

We provide a complete solutions including site survey, propose professional plan according to customer’s request ,technical support, and maintenance service for Telecommunication Companies in and out of China. We have a competent team and a network of trusted Partners around the world.

FAQ :

1. How do you control the quality?

A:All products before the shipment are simulated usage scenarios, load and full load and current sharing test to ensure the quality of the product.

2. What is your minimum order quantity?

A:There is no minimum order quantity, and one can also be done. The only difference is the price and schedule.

3. Can you introduce your company?

A:I am very honored. I will send you the company’s introduction document later to give you a more comprehensive and direct introduction to our company’s information.

4. What are the advantages of your company?

A:Adequate inventory, and supply guarantee for the subsequent renewal of supply, flexible provided according to different to different needs of customers, providing different solutions.

5. Can i send samples?Report it to me along with the price?

A:You can send samples, the samples are subject to large pride, and the freight needs to be borne by you.

6. How do your company deal with the problem on quality?

A:Our company has been doing this industry for almost 10 years. It has already had a certain reputation. We will carefully analyze it. If it is indeed our quality problem, you can rest assured that it will do things according to the contract agreement and will never let you have any after the worries, our service team will be happy to serve you.

7 What about the quality ?

A:100% original with new package. we will test each item before posted to make sure each item with good quality.

8 How many months for guarantee ?

A: 1 year quality guarantee

9 How to deal with any inferior -quality goods ?

A: Goods can be post by with our charge of post fee for any bad quality products within guarantee time.

Inquiry Cart 0