Add to Cart
Eltek Rectifiers Flatpack2 60/3000 SHE 60Vdc 3000W 97.85 high efficiency module (Part No.241119.706)
The Flatpack2 60/3000 Super HE is contributing to setting the new industry standard for efficiency in the DC power market.
The Flatpack2 60/3000 Super HE is contributing to setting the new industry standard for efficiency in the DC power market.
With an efficiency up to 97.8% the Super HE is a premium rectifier particularly suitable for markets and applications where the energy is costly. In grid connected applications the payback time is down to 2 years compared to standard HE rectifiers, and in hybrid applications even faster.
The Flatpack2 60/3000 Super HE is fully compatible with Flatpack2 and Flatpack2 HE systems.
Parameters :
Flatpack2 60/3000 SHE | |
Model | 60/3000 SHE |
Part number | 241119.706 |
INPUT DATA | |
Voltage (nominal range) | 206 - 264 VAC |
Voltage (operating range) | 85 - 264 VAC |
Frequency | 45 - 66 Hz |
Maximum current | 16 ARMS |
Protection | Fuse in Live, varistor for transient protection, shutdown when VIN is out of range |
OUTPUT DATA | |
Voltage (default) | 67 VDC |
Voltage (adjustable range) | 54 - 72 VDC |
Max power, nominal input | 3000 W |
Max power, de-rated @VIN = 85 VAC | 1000 W |
Max current, @VOUT = 60 VDC | 50 A |
Current sharing | ±5.0% of max current |
Static voltage regulation (10-100% load) | ±0.5% |
Dynamic voltage regulation | ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms |
Hold up time (3000W load) | >10ms; output voltage > 52.5 VDC |
Ripple | < 150 mVPP , 30 MHz bandwidth |
| Overvoltage shutdown, short circuit proof, high temperature, hot plug-in inrush current limiting, fuse |
OTHER SPECIFICATIONS | |
Peak Efficiency | 97.8 % |
| 3.0 kVAC – input to output 1.5 kVAC – input to protective earth 0.6 kVDC – output to protective earth |
| Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure (triggered in combination with high internal temperature), Low voltage alarm, CAN bus failure |
Warnings (Yellow LED) | Rectifier in power derate mode, Remote current limit activated, Input voltage out of range, flashing at overvoltage |
Normal (Green LED) | Input and output ok |
Operating temperature (5 - 95% RH non-cond.) | -40 - 75°C [-40 - 167°F ] |
Max output power de-rates above temp / to | 3000W @ 45°C / 1800 W @ 75°C1) |
MTBF (Telcordia SR-332 Iss.3 method II Case | > 1 500 000 hours |
Dimensions[WxHxD] / Weight | 109 x 41.0 x 327mm [4.25 x 1.61 x 13”] / 2.050 kg [4.5lbs] |
DESIGN STANDARDS | |
Electrical safety | IEC 62368-1, EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 |
| EN 61000-6-1:2016, -6-2:2016, -6-3:2007 + A1:2011, -6-4:2007 + A1:2011 EN 300 386:v2.1.1, FCC CFR 47 Part 15:2013 |
| ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) EU 2015/863 (RoHS) & 2012/19/EU (WEEE) Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised |
1) When input mains voltage is below 210 VRMS temperature derating will start at 40 °C and 1500 W will be available at 75 °C |
Solutions
Our comprehensive solutions are tailored for Telecommunication Companies in China and around the world. We conduct a meticulous site survey to understand the site's characteristics and potential. We then develop professional and customized plans that are aligned with the customer's business goals. Our technical support is highly skilled and responsive, providing timely assistance, and our maintenance services keep the telecom infrastructure in excellent condition. With a competent team and a vast network of trusted partners, we are committed to delivering superior services.
FAQ :
1.Q: Is it feasible to obtain product samples and pricing?
2.Q: How do you address quality - related concerns?
3.Q: What level of quality can I anticipate from your products?
4.Q: How long is the product’s quality guarantee?
5.Q: What's the solution for low - quality products?